Data series · Chapter 10

Scenario 3 — Pressure build-up and venting

Continued heating up to boiling. B4 switches in the first step after 2.8 bar is exceeded (t = 1470 s); after 120 s of venting the pressure is back at 0.0 bar.

Scenario
3 Pressure build-up
Expectation (criterion)
B4 when 2.8 bar is exceeded
Measurement
B4 in the first step thereafter (t = 1470.45 s); 0.0 bar after 120 s of venting
Result
passed
Rows
25,809
Time range
300.05–1,590.45 s
Time step
Δt = 0.05 s
Columns
9

Time series

Each quantity has its own axis and unit in its own panel; all share the time axis. The sensor bits appear as step lines. Clicking the legend shows or hides a quantity.

Time series of the measurement

Building the chart …

Quantities (click to show or hide)

    Controls: ← → move cursor (with ⇧ ten times) · Pos1 Ende to the edge · + − zoom · Bild↑ Bild↓ pan · 0 full series · Esc remove cursor. Drag a region with the mouse to zoom in. Values at the cursor belong to the nearest plotted data point; when zoomed far out the chart shows the minimum and maximum per pixel bucket so that single peaks stay visible. Exact values: zoom in or use the tables.

    Column description

    Name and unit come from the header row of the CSV file; the meaning follows the heated-tank model (chapter 8) and the recording (chapter 10).

    Columns of the series — Scenario 3 — Pressure build-up and venting
    No.Column (CSV header) UnitTypeMeaning
    1 Zeit (s) s Time axis Time stamp of the row (model time); one row per calculation step of Δt = 0.05 s.
    2 Füllstand (l) l Process variable Water level in the tank (tank volume 0.5 m³ = 500 l).
    3 Temperatur (°C) °C Process variable Water temperature, calculated from energy and water mass.
    4 Druck (bar) bar Process variable Pressure in the head space (steam and air, partial pressures added).
    5 Heizleistung (W) W Process variable Currently effective heating power (PT1 lag, τ = 12 s, up to 150 kW).
    6 B1 Füllstand max — Sensor bit (0/1) Upper level sensor: 1 from 450 l, otherwise 0.
    7 B2 Füllstand min — Sensor bit (0/1) Lower level sensor: 1 at 50 l or less, otherwise 0.
    8 B3 Temperatur ≥95 °C — Sensor bit (0/1) Temperature sensor: 1 from 95 °C, otherwise 0.
    9 B4 Druck ≥2,8 bar — Sensor bit (0/1) Pressure sensor: 1 from 2.8 bar, otherwise 0.

    Statistics of the series

    All figures are computed from the rows of the CSV file (over the whole series, without smoothing) and describe this single run only. They make no statement about a real tank.

    25,809Rows (calculation steps)
    1,290.45stime covered
    0.05sTime step Δt
    8recorded quantities
    Statistics per process variable — Scenario 3 — Pressure build-up and venting
    QuantityUnit CountMinimum MaximumMean First valueLast value
    Füllstand l 25,809 404.91t = 1,590.45 s 450.05t = 300.05 s 444.898 450.05 404.91
    Temperatur °C 25,809 39.572t = 300.05 s 122.732t = 1,470.40 s 87.1250 39.572 100.511
    Druck bar 25,809 0.0000t = 300.05 s 2.8048t = 1,470.45 s 0.3462 0.0000 0.0000
    Heizleistung W 25,809 150,000.0constant 150,000.0 150,000.00 150,000.0 150,000.0

    Below each extreme value is the time of the first row with that value. The mean is the simple mean over all rows (equal time steps).

    Sensor bits: switching times — Scenario 3 — Pressure build-up and venting
    Sensor bit Rows with 1 Share first 1 at then 0 again at Changes
    B1 Füllstand max 15,020 58.197 % 300.05 sfirst row 1,051.05 s 1
    B2 Füllstand min 0 0.000 % — — 0
    B3 Temperatur ≥95 °C 12,184 47.208 % 981.30 s — 1
    B4 Druck ≥2,8 bar 1 0.004 % 1,470.45 s 1,470.50 s 2

    1 means the sensor is active (threshold reached), 0 not active (chapter 8). “Changes” counts the rows in which the value differs from the previous row.

    Values

    All rows of the CSV file, unchanged, 100 rows per page. Search and sorting run on the server; you can jump to a row or a time. “No.” is a running row number and not part of the CSV.

    9,801–9,900 of 25,809 rows Download CSV
    Values — Scenario 3 — Pressure build-up and venting
    No. Zeit (s) Füllstand (l) Temperatur (°C) Druck (bar) Heizleistung (W) B1 Füllstand max B2 Füllstand min B3 Temperatur ≥95 °C B4 Druck ≥2,8 bar
    9,801 790.05450.0579.440.0150000.01000
    9,802 790.1450.0579.4440.0150000.01000
    9,803 790.15450.0579.4480.0150000.01000
    9,804 790.2450.0579.4520.0150000.01000
    9,805 790.25450.0579.4560.0150000.01000
    9,806 790.3450.0579.460.0150000.01000
    9,807 790.35450.0579.4640.0150000.01000
    9,808 790.4450.0579.4680.0150000.01000
    9,809 790.45450.0579.4730.0150000.01000
    9,810 790.5450.0579.4770.0150000.01000
    9,811 790.55450.0579.4810.0150000.01000
    9,812 790.6450.0579.4850.0150000.01000
    9,813 790.65450.0579.4890.0150000.01000
    9,814 790.7450.0579.4930.0150000.01000
    9,815 790.75450.0579.4970.0150000.01000
    9,816 790.8450.0579.5010.0150000.01000
    9,817 790.85450.0579.5050.0150000.01000
    9,818 790.9450.0579.5090.0150000.01000
    9,819 790.95450.0579.5130.0150000.01000
    9,820 791.0450.0579.5170.0150000.01000
    9,821 791.05450.0579.5210.0150000.01000
    9,822 791.1450.0579.5250.0150000.01000
    9,823 791.15450.0579.5290.0150000.01000
    9,824 791.2450.0579.5340.0150000.01000
    9,825 791.25450.0579.5380.0150000.01000
    9,826 791.3450.0579.5420.0150000.01000
    9,827 791.35450.0579.5460.0150000.01000
    9,828 791.4450.0579.550.0150000.01000
    9,829 791.45450.0579.5540.0150000.01000
    9,830 791.5450.0579.5580.0150000.01000
    9,831 791.55450.0579.5620.0150000.01000
    9,832 791.6450.0579.5660.0150000.01000
    9,833 791.65450.0579.570.0150000.01000
    9,834 791.7450.0579.5740.0150000.01000
    9,835 791.75450.0579.5780.0150000.01000
    9,836 791.8450.0579.5820.0150000.01000
    9,837 791.85450.0579.5860.0150000.01000
    9,838 791.9450.0579.590.0150000.01000
    9,839 791.95450.0579.5950.0150000.01000
    9,840 792.0450.0579.5990.0150000.01000
    9,841 792.05450.0579.6030.0150000.01000
    9,842 792.1450.0579.6070.0150000.01000
    9,843 792.15450.0579.6110.0150000.01000
    9,844 792.2450.0579.6150.0150000.01000
    9,845 792.25450.0579.6190.0150000.01000
    9,846 792.3450.0579.6230.0150000.01000
    9,847 792.35450.0579.6270.0150000.01000
    9,848 792.4450.0579.6310.0150000.01000
    9,849 792.45450.0579.6350.0150000.01000
    9,850 792.5450.0579.6390.0150000.01000
    9,851 792.55450.0579.6430.0150000.01000
    9,852 792.6450.0579.6470.0150000.01000
    9,853 792.65450.0579.6520.0150000.01000
    9,854 792.7450.0579.6560.0150000.01000
    9,855 792.75450.0579.660.0150000.01000
    9,856 792.8450.0579.6640.0150000.01000
    9,857 792.85450.0579.6680.0150000.01000
    9,858 792.9450.0579.6720.0150000.01000
    9,859 792.95450.0579.6760.0150000.01000
    9,860 793.0450.0579.680.0150000.01000
    9,861 793.05450.0579.6840.0150000.01000
    9,862 793.1450.0579.6880.0150000.01000
    9,863 793.15450.0579.6920.0150000.01000
    9,864 793.2450.0579.6960.0150000.01000
    9,865 793.25450.0579.70.0150000.01000
    9,866 793.3450.0579.7040.0150000.01000
    9,867 793.35450.0579.7080.0150000.01000
    9,868 793.4450.0579.7130.0150000.01000
    9,869 793.45450.0579.7170.0150000.01000
    9,870 793.5450.0579.7210.0150000.01000
    9,871 793.55450.0579.7250.0150000.01000
    9,872 793.6450.0579.7290.0150000.01000
    9,873 793.65450.0579.7330.0150000.01000
    9,874 793.7450.0579.7370.0150000.01000
    9,875 793.75450.0579.7410.0150000.01000
    9,876 793.8450.0579.7450.0150000.01000
    9,877 793.85450.0579.7490.0150000.01000
    9,878 793.9450.0579.7530.0150000.01000
    9,879 793.95450.0579.7570.0150000.01000
    9,880 794.0450.0579.7610.0150000.01000
    9,881 794.05450.0579.7650.0150000.01000
    9,882 794.1450.0579.7690.0150000.01000
    9,883 794.15450.0579.7740.0150000.01000
    9,884 794.2450.0579.7780.0150000.01000
    9,885 794.25450.0579.7820.0150000.01000
    9,886 794.3450.0579.7860.0150000.01000
    9,887 794.35450.0579.790.0150000.01000
    9,888 794.4450.0579.7940.0150000.01000
    9,889 794.45450.0579.7980.0150000.01000
    9,890 794.5450.0579.8020.0150000.01000
    9,891 794.55450.0579.8060.0150000.01000
    9,892 794.6450.0579.810.0150000.01000
    9,893 794.65450.0579.8140.0150000.01000
    9,894 794.7450.0579.8180.0150000.01000
    9,895 794.75450.0579.8220.0150000.01000
    9,896 794.8450.0579.8260.0150000.01000
    9,897 794.85450.0579.8310.0150000.01000
    9,898 794.9450.0579.8350.0150000.01000
    9,899 794.95450.0579.8390.0150000.01000
    9,900 795.0450.0579.8430.0150000.01000

    Source and citation

    Data source: Own measurement series, recorded on the model function compute_step (step size Δt = 0.05 s) according to the test log of the bachelor thesis (2026); set-up and evaluation see Chapter 10 — Five test scenarios.

    How to cite

    Kotsch, A. H. (2026): Dataset „Scenario 3 — Pressure build-up and venting“ (25,809 rows, time 300.05–1,590.45 s). Supplement to the bachelor thesis „Digital twins for PLC-coupled laboratory systems“, Duale Hochschule Sachsen — Studienakademie Glauchau. https://thesis.kotsch.tech/daten/szenario-3-druckaufbau (accessed 2026-10-02).

    Limits of this data
    • Classification (chapter 10): B4 is set in exactly the step in which the threshold is exceeded.
    • Limit: The calculated pressure follows a sawtooth pattern; the threshold is exceeded by a single pressure peak, and the moment depends on the fluctuation band. In twelve rows (from t = 1051.05 s) the level, rounded to 0.01 l, is 450.0 l while B1 is already 0; this is compatible with the rounding of the recording.
    • The expected values come from hand calculation and the analytical solution with the parameters of the model; agreement shows the correct implementation, not the accuracy compared with a real tank. Each scenario covers a single run with fixed boundary conditions. (Chapter 10)
    • Without measurement data from a real tank, validation is limited to internal consistency. (Chapter 11)