Data series · Chapter 10

Scenario 3 — Pressure build-up and venting

Continued heating up to boiling. B4 switches in the first step after 2.8 bar is exceeded (t = 1470 s); after 120 s of venting the pressure is back at 0.0 bar.

Scenario
3 Pressure build-up
Expectation (criterion)
B4 when 2.8 bar is exceeded
Measurement
B4 in the first step thereafter (t = 1470.45 s); 0.0 bar after 120 s of venting
Result
passed
Rows
25,809
Time range
300.05–1,590.45 s
Time step
Δt = 0.05 s
Columns
9

Time series

Each quantity has its own axis and unit in its own panel; all share the time axis. The sensor bits appear as step lines. Clicking the legend shows or hides a quantity.

Time series of the measurement

Building the chart …

Quantities (click to show or hide)

    Controls: ← → move cursor (with ⇧ ten times) · Pos1 Ende to the edge · + − zoom · Bild↑ Bild↓ pan · 0 full series · Esc remove cursor. Drag a region with the mouse to zoom in. Values at the cursor belong to the nearest plotted data point; when zoomed far out the chart shows the minimum and maximum per pixel bucket so that single peaks stay visible. Exact values: zoom in or use the tables.

    Column description

    Name and unit come from the header row of the CSV file; the meaning follows the heated-tank model (chapter 8) and the recording (chapter 10).

    Columns of the series — Scenario 3 — Pressure build-up and venting
    No.Column (CSV header) UnitTypeMeaning
    1 Zeit (s) s Time axis Time stamp of the row (model time); one row per calculation step of Δt = 0.05 s.
    2 Füllstand (l) l Process variable Water level in the tank (tank volume 0.5 m³ = 500 l).
    3 Temperatur (°C) °C Process variable Water temperature, calculated from energy and water mass.
    4 Druck (bar) bar Process variable Pressure in the head space (steam and air, partial pressures added).
    5 Heizleistung (W) W Process variable Currently effective heating power (PT1 lag, τ = 12 s, up to 150 kW).
    6 B1 Füllstand max — Sensor bit (0/1) Upper level sensor: 1 from 450 l, otherwise 0.
    7 B2 Füllstand min — Sensor bit (0/1) Lower level sensor: 1 at 50 l or less, otherwise 0.
    8 B3 Temperatur ≥95 °C — Sensor bit (0/1) Temperature sensor: 1 from 95 °C, otherwise 0.
    9 B4 Druck ≥2,8 bar — Sensor bit (0/1) Pressure sensor: 1 from 2.8 bar, otherwise 0.

    Statistics of the series

    All figures are computed from the rows of the CSV file (over the whole series, without smoothing) and describe this single run only. They make no statement about a real tank.

    25,809Rows (calculation steps)
    1,290.45stime covered
    0.05sTime step Δt
    8recorded quantities
    Statistics per process variable — Scenario 3 — Pressure build-up and venting
    QuantityUnit CountMinimum MaximumMean First valueLast value
    Füllstand l 25,809 404.91t = 1,590.45 s 450.05t = 300.05 s 444.898 450.05 404.91
    Temperatur °C 25,809 39.572t = 300.05 s 122.732t = 1,470.40 s 87.1250 39.572 100.511
    Druck bar 25,809 0.0000t = 300.05 s 2.8048t = 1,470.45 s 0.3462 0.0000 0.0000
    Heizleistung W 25,809 150,000.0constant 150,000.0 150,000.00 150,000.0 150,000.0

    Below each extreme value is the time of the first row with that value. The mean is the simple mean over all rows (equal time steps).

    Sensor bits: switching times — Scenario 3 — Pressure build-up and venting
    Sensor bit Rows with 1 Share first 1 at then 0 again at Changes
    B1 Füllstand max 15,020 58.197 % 300.05 sfirst row 1,051.05 s 1
    B2 Füllstand min 0 0.000 % — — 0
    B3 Temperatur ≥95 °C 12,184 47.208 % 981.30 s — 1
    B4 Druck ≥2,8 bar 1 0.004 % 1,470.45 s 1,470.50 s 2

    1 means the sensor is active (threshold reached), 0 not active (chapter 8). “Changes” counts the rows in which the value differs from the previous row.

    Values

    All rows of the CSV file, unchanged, 100 rows per page. Search and sorting run on the server; you can jump to a row or a time. “No.” is a running row number and not part of the CSV.

    11,701–11,800 of 25,809 rows Download CSV
    Values — Scenario 3 — Pressure build-up and venting
    No. Zeit (s) Füllstand (l) Temperatur (°C) Druck (bar) Heizleistung (W) B1 Füllstand max B2 Füllstand min B3 Temperatur ≥95 °C B4 Druck ≥2,8 bar
    11,701 885.05450.0587.1690.0150000.01000
    11,702 885.1450.0587.1740.0150000.01000
    11,703 885.15450.0587.1780.0150000.01000
    11,704 885.2450.0587.1820.0150000.01000
    11,705 885.25450.0587.1860.0150000.01000
    11,706 885.3450.0587.190.0150000.01000
    11,707 885.35450.0587.1940.0150000.01000
    11,708 885.4450.0587.1980.0150000.01000
    11,709 885.45450.0587.2020.0150000.01000
    11,710 885.5450.0587.2060.0150000.01000
    11,711 885.55450.0587.210.0150000.01000
    11,712 885.6450.0587.2140.0150000.01000
    11,713 885.65450.0587.2180.0150000.01000
    11,714 885.7450.0587.2220.0150000.01000
    11,715 885.75450.0587.2260.0150000.01000
    11,716 885.8450.0587.230.0150000.01000
    11,717 885.85450.0587.2350.0150000.01000
    11,718 885.9450.0587.2390.0150000.01000
    11,719 885.95450.0587.2430.0150000.01000
    11,720 886.0450.0587.2470.0150000.01000
    11,721 886.05450.0587.2510.0150000.01000
    11,722 886.1450.0587.2550.0150000.01000
    11,723 886.15450.0587.2590.0150000.01000
    11,724 886.2450.0587.2630.0150000.01000
    11,725 886.25450.0587.2670.0150000.01000
    11,726 886.3450.0587.2710.0150000.01000
    11,727 886.35450.0587.2750.0150000.01000
    11,728 886.4450.0587.2790.0150000.01000
    11,729 886.45450.0587.2830.0150000.01000
    11,730 886.5450.0587.2870.0150000.01000
    11,731 886.55450.0587.2920.0150000.01000
    11,732 886.6450.0587.2960.0150000.01000
    11,733 886.65450.0587.30.0150000.01000
    11,734 886.7450.0587.3040.0150000.01000
    11,735 886.75450.0587.3080.0150000.01000
    11,736 886.8450.0587.3120.0150000.01000
    11,737 886.85450.0587.3160.0150000.01000
    11,738 886.9450.0587.320.0150000.01000
    11,739 886.95450.0587.3240.0150000.01000
    11,740 887.0450.0587.3280.0150000.01000
    11,741 887.05450.0587.3320.0150000.01000
    11,742 887.1450.0587.3360.0150000.01000
    11,743 887.15450.0587.340.0150000.01000
    11,744 887.2450.0587.3440.0150000.01000
    11,745 887.25450.0587.3480.0150000.01000
    11,746 887.3450.0587.3530.0150000.01000
    11,747 887.35450.0587.3570.0150000.01000
    11,748 887.4450.0587.3610.0150000.01000
    11,749 887.45450.0587.3650.0150000.01000
    11,750 887.5450.0587.3690.0150000.01000
    11,751 887.55450.0587.3730.0150000.01000
    11,752 887.6450.0587.3770.0150000.01000
    11,753 887.65450.0587.3810.0150000.01000
    11,754 887.7450.0587.3850.0150000.01000
    11,755 887.75450.0587.3890.0150000.01000
    11,756 887.8450.0587.3930.0150000.01000
    11,757 887.85450.0587.3970.0150000.01000
    11,758 887.9450.0587.4010.0150000.01000
    11,759 887.95450.0587.4050.0150000.01000
    11,760 888.0450.0587.4090.0150000.01000
    11,761 888.05450.0587.4140.0150000.01000
    11,762 888.1450.0587.4180.0150000.01000
    11,763 888.15450.0587.4220.0150000.01000
    11,764 888.2450.0587.4260.0150000.01000
    11,765 888.25450.0587.430.0150000.01000
    11,766 888.3450.0587.4340.0150000.01000
    11,767 888.35450.0587.4380.0150000.01000
    11,768 888.4450.0587.4420.0150000.01000
    11,769 888.45450.0587.4460.0150000.01000
    11,770 888.5450.0587.450.0150000.01000
    11,771 888.55450.0587.4540.0150000.01000
    11,772 888.6450.0587.4580.0150000.01000
    11,773 888.65450.0587.4620.0150000.01000
    11,774 888.7450.0587.4660.0150000.01000
    11,775 888.75450.0587.4710.0150000.01000
    11,776 888.8450.0587.4750.0150000.01000
    11,777 888.85450.0587.4790.0150000.01000
    11,778 888.9450.0587.4830.0150000.01000
    11,779 888.95450.0587.4870.0150000.01000
    11,780 889.0450.0587.4910.0150000.01000
    11,781 889.05450.0587.4950.0150000.01000
    11,782 889.1450.0587.4990.0150000.01000
    11,783 889.15450.0587.5030.0150000.01000
    11,784 889.2450.0587.5070.0150000.01000
    11,785 889.25450.0587.5110.0150000.01000
    11,786 889.3450.0587.5150.0150000.01000
    11,787 889.35450.0587.5190.0150000.01000
    11,788 889.4450.0587.5230.0150000.01000
    11,789 889.45450.0587.5270.0150000.01000
    11,790 889.5450.0587.5320.0150000.01000
    11,791 889.55450.0587.5360.0150000.01000
    11,792 889.6450.0587.540.0150000.01000
    11,793 889.65450.0587.5440.0150000.01000
    11,794 889.7450.0587.5480.0150000.01000
    11,795 889.75450.0587.5520.0150000.01000
    11,796 889.8450.0587.5560.0150000.01000
    11,797 889.85450.0587.560.0150000.01000
    11,798 889.9450.0587.5640.0150000.01000
    11,799 889.95450.0587.5680.0150000.01000
    11,800 890.0450.0587.5720.0150000.01000

    Source and citation

    Data source: Own measurement series, recorded on the model function compute_step (step size Δt = 0.05 s) according to the test log of the bachelor thesis (2026); set-up and evaluation see Chapter 10 — Five test scenarios.

    How to cite

    Kotsch, A. H. (2026): Dataset „Scenario 3 — Pressure build-up and venting“ (25,809 rows, time 300.05–1,590.45 s). Supplement to the bachelor thesis „Digital twins for PLC-coupled laboratory systems“, Duale Hochschule Sachsen — Studienakademie Glauchau. https://thesis.kotsch.tech/daten/szenario-3-druckaufbau (accessed 2026-10-02).

    Limits of this data
    • Classification (chapter 10): B4 is set in exactly the step in which the threshold is exceeded.
    • Limit: The calculated pressure follows a sawtooth pattern; the threshold is exceeded by a single pressure peak, and the moment depends on the fluctuation band. In twelve rows (from t = 1051.05 s) the level, rounded to 0.01 l, is 450.0 l while B1 is already 0; this is compatible with the rounding of the recording.
    • The expected values come from hand calculation and the analytical solution with the parameters of the model; agreement shows the correct implementation, not the accuracy compared with a real tank. Each scenario covers a single run with fixed boundary conditions. (Chapter 10)
    • Without measurement data from a real tank, validation is limited to internal consistency. (Chapter 11)