Data series · Chapter 10

Scenario 3 — Pressure build-up and venting

Continued heating up to boiling. B4 switches in the first step after 2.8 bar is exceeded (t = 1470 s); after 120 s of venting the pressure is back at 0.0 bar.

Scenario
3 Pressure build-up
Expectation (criterion)
B4 when 2.8 bar is exceeded
Measurement
B4 in the first step thereafter (t = 1470.45 s); 0.0 bar after 120 s of venting
Result
passed
Rows
25,809
Time range
300.05–1,590.45 s
Time step
Δt = 0.05 s
Columns
9

Time series

Each quantity has its own axis and unit in its own panel; all share the time axis. The sensor bits appear as step lines. Clicking the legend shows or hides a quantity.

Time series of the measurement

Building the chart …

Quantities (click to show or hide)

    Controls: ← → move cursor (with ⇧ ten times) · Pos1 Ende to the edge · + − zoom · Bild↑ Bild↓ pan · 0 full series · Esc remove cursor. Drag a region with the mouse to zoom in. Values at the cursor belong to the nearest plotted data point; when zoomed far out the chart shows the minimum and maximum per pixel bucket so that single peaks stay visible. Exact values: zoom in or use the tables.

    Column description

    Name and unit come from the header row of the CSV file; the meaning follows the heated-tank model (chapter 8) and the recording (chapter 10).

    Columns of the series — Scenario 3 — Pressure build-up and venting
    No.Column (CSV header) UnitTypeMeaning
    1 Zeit (s) s Time axis Time stamp of the row (model time); one row per calculation step of Δt = 0.05 s.
    2 Füllstand (l) l Process variable Water level in the tank (tank volume 0.5 m³ = 500 l).
    3 Temperatur (°C) °C Process variable Water temperature, calculated from energy and water mass.
    4 Druck (bar) bar Process variable Pressure in the head space (steam and air, partial pressures added).
    5 Heizleistung (W) W Process variable Currently effective heating power (PT1 lag, τ = 12 s, up to 150 kW).
    6 B1 Füllstand max — Sensor bit (0/1) Upper level sensor: 1 from 450 l, otherwise 0.
    7 B2 Füllstand min — Sensor bit (0/1) Lower level sensor: 1 at 50 l or less, otherwise 0.
    8 B3 Temperatur ≥95 °C — Sensor bit (0/1) Temperature sensor: 1 from 95 °C, otherwise 0.
    9 B4 Druck ≥2,8 bar — Sensor bit (0/1) Pressure sensor: 1 from 2.8 bar, otherwise 0.

    Statistics of the series

    All figures are computed from the rows of the CSV file (over the whole series, without smoothing) and describe this single run only. They make no statement about a real tank.

    25,809Rows (calculation steps)
    1,290.45stime covered
    0.05sTime step Δt
    8recorded quantities
    Statistics per process variable — Scenario 3 — Pressure build-up and venting
    QuantityUnit CountMinimum MaximumMean First valueLast value
    Füllstand l 25,809 404.91t = 1,590.45 s 450.05t = 300.05 s 444.898 450.05 404.91
    Temperatur °C 25,809 39.572t = 300.05 s 122.732t = 1,470.40 s 87.1250 39.572 100.511
    Druck bar 25,809 0.0000t = 300.05 s 2.8048t = 1,470.45 s 0.3462 0.0000 0.0000
    Heizleistung W 25,809 150,000.0constant 150,000.0 150,000.00 150,000.0 150,000.0

    Below each extreme value is the time of the first row with that value. The mean is the simple mean over all rows (equal time steps).

    Sensor bits: switching times — Scenario 3 — Pressure build-up and venting
    Sensor bit Rows with 1 Share first 1 at then 0 again at Changes
    B1 Füllstand max 15,020 58.197 % 300.05 sfirst row 1,051.05 s 1
    B2 Füllstand min 0 0.000 % — — 0
    B3 Temperatur ≥95 °C 12,184 47.208 % 981.30 s — 1
    B4 Druck ≥2,8 bar 1 0.004 % 1,470.45 s 1,470.50 s 2

    1 means the sensor is active (threshold reached), 0 not active (chapter 8). “Changes” counts the rows in which the value differs from the previous row.

    Values

    All rows of the CSV file, unchanged, 100 rows per page. Search and sorting run on the server; you can jump to a row or a time. “No.” is a running row number and not part of the CSV.

    7,901–8,000 of 25,809 rows Download CSV
    Values — Scenario 3 — Pressure build-up and venting
    No. Zeit (s) Füllstand (l) Temperatur (°C) Druck (bar) Heizleistung (W) B1 Füllstand max B2 Füllstand min B3 Temperatur ≥95 °C B4 Druck ≥2,8 bar
    7,901 695.05450.0571.710.0150000.01000
    7,902 695.1450.0571.7150.0150000.01000
    7,903 695.15450.0571.7190.0150000.01000
    7,904 695.2450.0571.7230.0150000.01000
    7,905 695.25450.0571.7270.0150000.01000
    7,906 695.3450.0571.7310.0150000.01000
    7,907 695.35450.0571.7350.0150000.01000
    7,908 695.4450.0571.7390.0150000.01000
    7,909 695.45450.0571.7430.0150000.01000
    7,910 695.5450.0571.7470.0150000.01000
    7,911 695.55450.0571.7510.0150000.01000
    7,912 695.6450.0571.7550.0150000.01000
    7,913 695.65450.0571.7590.0150000.01000
    7,914 695.7450.0571.7630.0150000.01000
    7,915 695.75450.0571.7670.0150000.01000
    7,916 695.8450.0571.7720.0150000.01000
    7,917 695.85450.0571.7760.0150000.01000
    7,918 695.9450.0571.780.0150000.01000
    7,919 695.95450.0571.7840.0150000.01000
    7,920 696.0450.0571.7880.0150000.01000
    7,921 696.05450.0571.7920.0150000.01000
    7,922 696.1450.0571.7960.0150000.01000
    7,923 696.15450.0571.80.0150000.01000
    7,924 696.2450.0571.8040.0150000.01000
    7,925 696.25450.0571.8080.0150000.01000
    7,926 696.3450.0571.8120.0150000.01000
    7,927 696.35450.0571.8160.0150000.01000
    7,928 696.4450.0571.820.0150000.01000
    7,929 696.45450.0571.8240.0150000.01000
    7,930 696.5450.0571.8280.0150000.01000
    7,931 696.55450.0571.8330.0150000.01000
    7,932 696.6450.0571.8370.0150000.01000
    7,933 696.65450.0571.8410.0150000.01000
    7,934 696.7450.0571.8450.0150000.01000
    7,935 696.75450.0571.8490.0150000.01000
    7,936 696.8450.0571.8530.0150000.01000
    7,937 696.85450.0571.8570.0150000.01000
    7,938 696.9450.0571.8610.0150000.01000
    7,939 696.95450.0571.8650.0150000.01000
    7,940 697.0450.0571.8690.0150000.01000
    7,941 697.05450.0571.8730.0150000.01000
    7,942 697.1450.0571.8770.0150000.01000
    7,943 697.15450.0571.8810.0150000.01000
    7,944 697.2450.0571.8850.0150000.01000
    7,945 697.25450.0571.8890.0150000.01000
    7,946 697.3450.0571.8940.0150000.01000
    7,947 697.35450.0571.8980.0150000.01000
    7,948 697.4450.0571.9020.0150000.01000
    7,949 697.45450.0571.9060.0150000.01000
    7,950 697.5450.0571.910.0150000.01000
    7,951 697.55450.0571.9140.0150000.01000
    7,952 697.6450.0571.9180.0150000.01000
    7,953 697.65450.0571.9220.0150000.01000
    7,954 697.7450.0571.9260.0150000.01000
    7,955 697.75450.0571.930.0150000.01000
    7,956 697.8450.0571.9340.0150000.01000
    7,957 697.85450.0571.9380.0150000.01000
    7,958 697.9450.0571.9420.0150000.01000
    7,959 697.95450.0571.9460.0150000.01000
    7,960 698.0450.0571.9510.0150000.01000
    7,961 698.05450.0571.9550.0150000.01000
    7,962 698.1450.0571.9590.0150000.01000
    7,963 698.15450.0571.9630.0150000.01000
    7,964 698.2450.0571.9670.0150000.01000
    7,965 698.25450.0571.9710.0150000.01000
    7,966 698.3450.0571.9750.0150000.01000
    7,967 698.35450.0571.9790.0150000.01000
    7,968 698.4450.0571.9830.0150000.01000
    7,969 698.45450.0571.9870.0150000.01000
    7,970 698.5450.0571.9910.0150000.01000
    7,971 698.55450.0571.9950.0150000.01000
    7,972 698.6450.0571.9990.0150000.01000
    7,973 698.65450.0572.0030.0150000.01000
    7,974 698.7450.0572.0070.0150000.01000
    7,975 698.75450.0572.0120.0150000.01000
    7,976 698.8450.0572.0160.0150000.01000
    7,977 698.85450.0572.020.0150000.01000
    7,978 698.9450.0572.0240.0150000.01000
    7,979 698.95450.0572.0280.0150000.01000
    7,980 699.0450.0572.0320.0150000.01000
    7,981 699.05450.0572.0360.0150000.01000
    7,982 699.1450.0572.040.0150000.01000
    7,983 699.15450.0572.0440.0150000.01000
    7,984 699.2450.0572.0480.0150000.01000
    7,985 699.25450.0572.0520.0150000.01000
    7,986 699.3450.0572.0560.0150000.01000
    7,987 699.35450.0572.060.0150000.01000
    7,988 699.4450.0572.0640.0150000.01000
    7,989 699.45450.0572.0680.0150000.01000
    7,990 699.5450.0572.0730.0150000.01000
    7,991 699.55450.0572.0770.0150000.01000
    7,992 699.6450.0572.0810.0150000.01000
    7,993 699.65450.0572.0850.0150000.01000
    7,994 699.7450.0572.0890.0150000.01000
    7,995 699.75450.0572.0930.0150000.01000
    7,996 699.8450.0572.0970.0150000.01000
    7,997 699.85450.0572.1010.0150000.01000
    7,998 699.9450.0572.1050.0150000.01000
    7,999 699.95450.0572.1090.0150000.01000
    8,000 700.0450.0572.1130.0150000.01000

    Source and citation

    Data source: Own measurement series, recorded on the model function compute_step (step size Δt = 0.05 s) according to the test log of the bachelor thesis (2026); set-up and evaluation see Chapter 10 — Five test scenarios.

    How to cite

    Kotsch, A. H. (2026): Dataset „Scenario 3 — Pressure build-up and venting“ (25,809 rows, time 300.05–1,590.45 s). Supplement to the bachelor thesis „Digital twins for PLC-coupled laboratory systems“, Duale Hochschule Sachsen — Studienakademie Glauchau. https://thesis.kotsch.tech/daten/szenario-3-druckaufbau (accessed 2026-10-01).

    Limits of this data
    • Classification (chapter 10): B4 is set in exactly the step in which the threshold is exceeded.
    • Limit: The calculated pressure follows a sawtooth pattern; the threshold is exceeded by a single pressure peak, and the moment depends on the fluctuation band. In twelve rows (from t = 1051.05 s) the level, rounded to 0.01 l, is 450.0 l while B1 is already 0; this is compatible with the rounding of the recording.
    • The expected values come from hand calculation and the analytical solution with the parameters of the model; agreement shows the correct implementation, not the accuracy compared with a real tank. Each scenario covers a single run with fixed boundary conditions. (Chapter 10)
    • Without measurement data from a real tank, validation is limited to internal consistency. (Chapter 11)