Data series · Chapter 10

Scenario 2 — Heating with PT1 behaviour

Step to 150 kW heating power, time constant 12 s. Reaches 63.3 % at t = τ and 95.1 % at 3τ; mean deviation from the analytical solution 0.040 %.

Scenario
2 Heating
Expectation (criterion)
heating rate 0.0814 K/s; PT1 63.2 % at τ, 95.0 % at 3τ
Measurement
63.3 % at τ, 95.1 % at 3τ; mean deviation 0.040 % of maximum power
Result
passed
Rows
6,000
Time range
0.05–300.00 s
Time step
Δt = 0.05 s
Columns
9

Time series

Each quantity has its own axis and unit in its own panel; all share the time axis. The sensor bits appear as step lines. Clicking the legend shows or hides a quantity.

Time series of the measurement

Building the chart …

Quantities (click to show or hide)

    Controls: ← → move cursor (with ⇧ ten times) · Pos1 Ende to the edge · + − zoom · Bild↑ Bild↓ pan · 0 full series · Esc remove cursor. Drag a region with the mouse to zoom in. Values at the cursor belong to the nearest plotted data point; when zoomed far out the chart shows the minimum and maximum per pixel bucket so that single peaks stay visible. Exact values: zoom in or use the tables.

    Column description

    Name and unit come from the header row of the CSV file; the meaning follows the heated-tank model (chapter 8) and the recording (chapter 10).

    Columns of the series — Scenario 2 — Heating with PT1 behaviour
    No.Column (CSV header) UnitTypeMeaning
    1 Zeit (s) s Time axis Time stamp of the row (model time); one row per calculation step of Δt = 0.05 s.
    2 Füllstand (l) l Process variable Water level in the tank (tank volume 0.5 m³ = 500 l).
    3 Temperatur (°C) °C Process variable Water temperature, calculated from energy and water mass.
    4 Druck (bar) bar Process variable Pressure in the head space (steam and air, partial pressures added).
    5 Heizleistung (W) W Process variable Currently effective heating power (PT1 lag, τ = 12 s, up to 150 kW).
    6 B1 Füllstand max — Sensor bit (0/1) Upper level sensor: 1 from 450 l, otherwise 0.
    7 B2 Füllstand min — Sensor bit (0/1) Lower level sensor: 1 at 50 l or less, otherwise 0.
    8 B3 Temperatur ≥95 °C — Sensor bit (0/1) Temperature sensor: 1 from 95 °C, otherwise 0.
    9 B4 Druck ≥2,8 bar — Sensor bit (0/1) Pressure sensor: 1 from 2.8 bar, otherwise 0.

    Statistics of the series

    All figures are computed from the rows of the CSV file (over the whole series, without smoothing) and describe this single run only. They make no statement about a real tank.

    6,000Rows (calculation steps)
    300.00stime covered
    0.05sTime step Δt
    8recorded quantities
    Statistics per process variable — Scenario 2 — Heating with PT1 behaviour
    QuantityUnit CountMinimum MaximumMean First valueLast value
    Füllstand l 6,000 450.05constant 450.05 450.050 450.05 450.05
    Temperatur °C 6,000 16.131t = 0.05 s 39.568t = 300.00 s 27.4043 16.131 39.568
    Druck bar 6,000 0.0000t = 0.30 s 0.0072t = 0.05 s 0.0000 0.0072 0.0000
    Heizleistung W 6,000 625.0t = 0.05 s 150,000.0t = 178.60 s 144,025.00 625.0 150,000.0

    Below each extreme value is the time of the first row with that value. The mean is the simple mean over all rows (equal time steps).

    Sensor bits: switching times — Scenario 2 — Heating with PT1 behaviour
    Sensor bit Rows with 1 Share first 1 at then 0 again at Changes
    B1 Füllstand max 6,000 100.000 % 0.05 sfirst row — 0
    B2 Füllstand min 0 0.000 % — — 0
    B3 Temperatur ≥95 °C 0 0.000 % — — 0
    B4 Druck ≥2,8 bar 0 0.000 % — — 0

    1 means the sensor is active (threshold reached), 0 not active (chapter 8). “Changes” counts the rows in which the value differs from the previous row.

    Values

    All rows of the CSV file, unchanged, 100 rows per page. Search and sorting run on the server; you can jump to a row or a time. “No.” is a running row number and not part of the CSV.

    1,701–1,800 of 6,000 rows Download CSV
    Values — Scenario 2 — Heating with PT1 behaviour
    No. Zeit (s) Füllstand (l) Temperatur (°C) Druck (bar) Heizleistung (W) B1 Füllstand max B2 Füllstand min B3 Temperatur ≥95 °C B4 Druck ≥2,8 bar
    1,701 85.05450.0522.080.0149876.51000
    1,702 85.1450.0522.0840.0149877.01000
    1,703 85.15450.0522.0880.0149877.51000
    1,704 85.2450.0522.0920.0149878.11000
    1,705 85.25450.0522.0960.0149878.61000
    1,706 85.3450.0522.10.0149879.11000
    1,707 85.35450.0522.1040.0149879.61000
    1,708 85.4450.0522.1080.0149880.11000
    1,709 85.45450.0522.1120.0149880.61000
    1,710 85.5450.0522.1160.0149881.11000
    1,711 85.55450.0522.120.0149881.61000
    1,712 85.6450.0522.1250.0149882.11000
    1,713 85.65450.0522.1290.0149882.61000
    1,714 85.7450.0522.1330.0149883.01000
    1,715 85.75450.0522.1370.0149883.51000
    1,716 85.8450.0522.1410.0149884.01000
    1,717 85.85450.0522.1450.0149884.51000
    1,718 85.9450.0522.1490.0149885.01000
    1,719 85.95450.0522.1530.0149885.51000
    1,720 86.0450.0522.1570.0149885.91000
    1,721 86.05450.0522.1610.0149886.41000
    1,722 86.1450.0522.1650.0149886.91000
    1,723 86.15450.0522.1690.0149887.41000
    1,724 86.2450.0522.1730.0149887.81000
    1,725 86.25450.0522.1770.0149888.31000
    1,726 86.3450.0522.1810.0149888.81000
    1,727 86.35450.0522.1860.0149889.21000
    1,728 86.4450.0522.190.0149889.71000
    1,729 86.45450.0522.1940.0149890.11000
    1,730 86.5450.0522.1980.0149890.61000
    1,731 86.55450.0522.2020.0149891.11000
    1,732 86.6450.0522.2060.0149891.51000
    1,733 86.65450.0522.210.0149892.01000
    1,734 86.7450.0522.2140.0149892.41000
    1,735 86.75450.0522.2180.0149892.91000
    1,736 86.8450.0522.2220.0149893.31000
    1,737 86.85450.0522.2260.0149893.81000
    1,738 86.9450.0522.230.0149894.21000
    1,739 86.95450.0522.2340.0149894.61000
    1,740 87.0450.0522.2380.0149895.11000
    1,741 87.05450.0522.2420.0149895.51000
    1,742 87.1450.0522.2460.0149895.91000
    1,743 87.15450.0522.2510.0149896.41000
    1,744 87.2450.0522.2550.0149896.81000
    1,745 87.25450.0522.2590.0149897.21000
    1,746 87.3450.0522.2630.0149897.71000
    1,747 87.35450.0522.2670.0149898.11000
    1,748 87.4450.0522.2710.0149898.51000
    1,749 87.45450.0522.2750.0149898.91000
    1,750 87.5450.0522.2790.0149899.41000
    1,751 87.55450.0522.2830.0149899.81000
    1,752 87.6450.0522.2870.0149900.21000
    1,753 87.65450.0522.2910.0149900.61000
    1,754 87.7450.0522.2950.0149901.01000
    1,755 87.75450.0522.2990.0149901.41000
    1,756 87.8450.0522.3030.0149901.91000
    1,757 87.85450.0522.3070.0149902.31000
    1,758 87.9450.0522.3120.0149902.71000
    1,759 87.95450.0522.3160.0149903.11000
    1,760 88.0450.0522.320.0149903.51000
    1,761 88.05450.0522.3240.0149903.91000
    1,762 88.1450.0522.3280.0149904.31000
    1,763 88.15450.0522.3320.0149904.71000
    1,764 88.2450.0522.3360.0149905.11000
    1,765 88.25450.0522.340.0149905.51000
    1,766 88.3450.0522.3440.0149905.91000
    1,767 88.35450.0522.3480.0149906.31000
    1,768 88.4450.0522.3520.0149906.71000
    1,769 88.45450.0522.3560.0149907.01000
    1,770 88.5450.0522.360.0149907.41000
    1,771 88.55450.0522.3640.0149907.81000
    1,772 88.6450.0522.3680.0149908.21000
    1,773 88.65450.0522.3730.0149908.61000
    1,774 88.7450.0522.3770.0149909.01000
    1,775 88.75450.0522.3810.0149909.31000
    1,776 88.8450.0522.3850.0149909.71000
    1,777 88.85450.0522.3890.0149910.11000
    1,778 88.9450.0522.3930.0149910.51000
    1,779 88.95450.0522.3970.0149910.81000
    1,780 89.0450.0522.4010.0149911.21000
    1,781 89.05450.0522.4050.0149911.61000
    1,782 89.1450.0522.4090.0149912.01000
    1,783 89.15450.0522.4130.0149912.31000
    1,784 89.2450.0522.4170.0149912.71000
    1,785 89.25450.0522.4210.0149913.01000
    1,786 89.3450.0522.4250.0149913.41000
    1,787 89.35450.0522.4290.0149913.81000
    1,788 89.4450.0522.4340.0149914.11000
    1,789 89.45450.0522.4380.0149914.51000
    1,790 89.5450.0522.4420.0149914.81000
    1,791 89.55450.0522.4460.0149915.21000
    1,792 89.6450.0522.450.0149915.61000
    1,793 89.65450.0522.4540.0149915.91000
    1,794 89.7450.0522.4580.0149916.31000
    1,795 89.75450.0522.4620.0149916.61000
    1,796 89.8450.0522.4660.0149917.01000
    1,797 89.85450.0522.470.0149917.31000
    1,798 89.9450.0522.4740.0149917.61000
    1,799 89.95450.0522.4780.0149918.01000
    1,800 90.0450.0522.4820.0149918.31000

    Source and citation

    Data source: Own measurement series, recorded on the model function compute_step (step size Δt = 0.05 s) according to the test log of the bachelor thesis (2026); set-up and evaluation see Chapter 10 — Five test scenarios.

    How to cite

    Kotsch, A. H. (2026): Dataset „Scenario 2 — Heating with PT1 behaviour“ (6,000 rows, time 0.05–300.00 s). Supplement to the bachelor thesis „Digital twins for PLC-coupled laboratory systems“, Duale Hochschule Sachsen — Studienakademie Glauchau. https://thesis.kotsch.tech/daten/szenario-2-heizen (accessed 2026-09-30).

    Limits of this data
    • Classification (chapter 10): The deviations are compatible with the discretisation error of the Euler method.
    • Limit: The expectation uses the same parameters (τ = 12 s, 150 kW); what is tested is the implementation of the equations, not their agreement with a real heating element.
    • The expected values come from hand calculation and the analytical solution with the parameters of the model; agreement shows the correct implementation, not the accuracy compared with a real tank. Each scenario covers a single run with fixed boundary conditions. (Chapter 10)
    • Without measurement data from a real tank, validation is limited to internal consistency. (Chapter 11)