Data series · Chapter 10

Scenario 2 — Heating with PT1 behaviour

Step to 150 kW heating power, time constant 12 s. Reaches 63.3 % at t = τ and 95.1 % at 3τ; mean deviation from the analytical solution 0.040 %.

Scenario
2 Heating
Expectation (criterion)
heating rate 0.0814 K/s; PT1 63.2 % at τ, 95.0 % at 3τ
Measurement
63.3 % at τ, 95.1 % at 3τ; mean deviation 0.040 % of maximum power
Result
passed
Rows
6,000
Time range
0.05–300.00 s
Time step
Δt = 0.05 s
Columns
9

Time series

Each quantity has its own axis and unit in its own panel; all share the time axis. The sensor bits appear as step lines. Clicking the legend shows or hides a quantity.

Time series of the measurement

Building the chart …

Quantities (click to show or hide)

    Controls: ← → move cursor (with ⇧ ten times) · Pos1 Ende to the edge · + − zoom · Bild↑ Bild↓ pan · 0 full series · Esc remove cursor. Drag a region with the mouse to zoom in. Values at the cursor belong to the nearest plotted data point; when zoomed far out the chart shows the minimum and maximum per pixel bucket so that single peaks stay visible. Exact values: zoom in or use the tables.

    Column description

    Name and unit come from the header row of the CSV file; the meaning follows the heated-tank model (chapter 8) and the recording (chapter 10).

    Columns of the series — Scenario 2 — Heating with PT1 behaviour
    No.Column (CSV header) UnitTypeMeaning
    1 Zeit (s) s Time axis Time stamp of the row (model time); one row per calculation step of Δt = 0.05 s.
    2 Füllstand (l) l Process variable Water level in the tank (tank volume 0.5 m³ = 500 l).
    3 Temperatur (°C) °C Process variable Water temperature, calculated from energy and water mass.
    4 Druck (bar) bar Process variable Pressure in the head space (steam and air, partial pressures added).
    5 Heizleistung (W) W Process variable Currently effective heating power (PT1 lag, τ = 12 s, up to 150 kW).
    6 B1 Füllstand max — Sensor bit (0/1) Upper level sensor: 1 from 450 l, otherwise 0.
    7 B2 Füllstand min — Sensor bit (0/1) Lower level sensor: 1 at 50 l or less, otherwise 0.
    8 B3 Temperatur ≥95 °C — Sensor bit (0/1) Temperature sensor: 1 from 95 °C, otherwise 0.
    9 B4 Druck ≥2,8 bar — Sensor bit (0/1) Pressure sensor: 1 from 2.8 bar, otherwise 0.

    Statistics of the series

    All figures are computed from the rows of the CSV file (over the whole series, without smoothing) and describe this single run only. They make no statement about a real tank.

    6,000Rows (calculation steps)
    300.00stime covered
    0.05sTime step Δt
    8recorded quantities
    Statistics per process variable — Scenario 2 — Heating with PT1 behaviour
    QuantityUnit CountMinimum MaximumMean First valueLast value
    Füllstand l 6,000 450.05constant 450.05 450.050 450.05 450.05
    Temperatur °C 6,000 16.131t = 0.05 s 39.568t = 300.00 s 27.4043 16.131 39.568
    Druck bar 6,000 0.0000t = 0.30 s 0.0072t = 0.05 s 0.0000 0.0072 0.0000
    Heizleistung W 6,000 625.0t = 0.05 s 150,000.0t = 178.60 s 144,025.00 625.0 150,000.0

    Below each extreme value is the time of the first row with that value. The mean is the simple mean over all rows (equal time steps).

    Sensor bits: switching times — Scenario 2 — Heating with PT1 behaviour
    Sensor bit Rows with 1 Share first 1 at then 0 again at Changes
    B1 Füllstand max 6,000 100.000 % 0.05 sfirst row — 0
    B2 Füllstand min 0 0.000 % — — 0
    B3 Temperatur ≥95 °C 0 0.000 % — — 0
    B4 Druck ≥2,8 bar 0 0.000 % — — 0

    1 means the sensor is active (threshold reached), 0 not active (chapter 8). “Changes” counts the rows in which the value differs from the previous row.

    Values

    All rows of the CSV file, unchanged, 100 rows per page. Search and sorting run on the server; you can jump to a row or a time. “No.” is a running row number and not part of the CSV.

    5,901–6,000 of 6,000 rows Download CSV
    Values — Scenario 2 — Heating with PT1 behaviour
    No. Zeit (s) Füllstand (l) Temperatur (°C) Druck (bar) Heizleistung (W) B1 Füllstand max B2 Füllstand min B3 Temperatur ≥95 °C B4 Druck ≥2,8 bar
    5,901 295.05450.0539.1650.0150000.01000
    5,902 295.1450.0539.1690.0150000.01000
    5,903 295.15450.0539.1730.0150000.01000
    5,904 295.2450.0539.1770.0150000.01000
    5,905 295.25450.0539.1820.0150000.01000
    5,906 295.3450.0539.1860.0150000.01000
    5,907 295.35450.0539.190.0150000.01000
    5,908 295.4450.0539.1940.0150000.01000
    5,909 295.45450.0539.1980.0150000.01000
    5,910 295.5450.0539.2020.0150000.01000
    5,911 295.55450.0539.2060.0150000.01000
    5,912 295.6450.0539.210.0150000.01000
    5,913 295.65450.0539.2140.0150000.01000
    5,914 295.7450.0539.2180.0150000.01000
    5,915 295.75450.0539.2220.0150000.01000
    5,916 295.8450.0539.2260.0150000.01000
    5,917 295.85450.0539.230.0150000.01000
    5,918 295.9450.0539.2340.0150000.01000
    5,919 295.95450.0539.2380.0150000.01000
    5,920 296.0450.0539.2430.0150000.01000
    5,921 296.05450.0539.2470.0150000.01000
    5,922 296.1450.0539.2510.0150000.01000
    5,923 296.15450.0539.2550.0150000.01000
    5,924 296.2450.0539.2590.0150000.01000
    5,925 296.25450.0539.2630.0150000.01000
    5,926 296.3450.0539.2670.0150000.01000
    5,927 296.35450.0539.2710.0150000.01000
    5,928 296.4450.0539.2750.0150000.01000
    5,929 296.45450.0539.2790.0150000.01000
    5,930 296.5450.0539.2830.0150000.01000
    5,931 296.55450.0539.2870.0150000.01000
    5,932 296.6450.0539.2910.0150000.01000
    5,933 296.65450.0539.2950.0150000.01000
    5,934 296.7450.0539.30.0150000.01000
    5,935 296.75450.0539.3040.0150000.01000
    5,936 296.8450.0539.3080.0150000.01000
    5,937 296.85450.0539.3120.0150000.01000
    5,938 296.9450.0539.3160.0150000.01000
    5,939 296.95450.0539.320.0150000.01000
    5,940 297.0450.0539.3240.0150000.01000
    5,941 297.05450.0539.3280.0150000.01000
    5,942 297.1450.0539.3320.0150000.01000
    5,943 297.15450.0539.3360.0150000.01000
    5,944 297.2450.0539.340.0150000.01000
    5,945 297.25450.0539.3440.0150000.01000
    5,946 297.3450.0539.3480.0150000.01000
    5,947 297.35450.0539.3520.0150000.01000
    5,948 297.4450.0539.3560.0150000.01000
    5,949 297.45450.0539.3610.0150000.01000
    5,950 297.5450.0539.3650.0150000.01000
    5,951 297.55450.0539.3690.0150000.01000
    5,952 297.6450.0539.3730.0150000.01000
    5,953 297.65450.0539.3770.0150000.01000
    5,954 297.7450.0539.3810.0150000.01000
    5,955 297.75450.0539.3850.0150000.01000
    5,956 297.8450.0539.3890.0150000.01000
    5,957 297.85450.0539.3930.0150000.01000
    5,958 297.9450.0539.3970.0150000.01000
    5,959 297.95450.0539.4010.0150000.01000
    5,960 298.0450.0539.4050.0150000.01000
    5,961 298.05450.0539.4090.0150000.01000
    5,962 298.1450.0539.4130.0150000.01000
    5,963 298.15450.0539.4170.0150000.01000
    5,964 298.2450.0539.4220.0150000.01000
    5,965 298.25450.0539.4260.0150000.01000
    5,966 298.3450.0539.430.0150000.01000
    5,967 298.35450.0539.4340.0150000.01000
    5,968 298.4450.0539.4380.0150000.01000
    5,969 298.45450.0539.4420.0150000.01000
    5,970 298.5450.0539.4460.0150000.01000
    5,971 298.55450.0539.450.0150000.01000
    5,972 298.6450.0539.4540.0150000.01000
    5,973 298.65450.0539.4580.0150000.01000
    5,974 298.7450.0539.4620.0150000.01000
    5,975 298.75450.0539.4660.0150000.01000
    5,976 298.8450.0539.470.0150000.01000
    5,977 298.85450.0539.4740.0150000.01000
    5,978 298.9450.0539.4790.0150000.01000
    5,979 298.95450.0539.4830.0150000.01000
    5,980 299.0450.0539.4870.0150000.01000
    5,981 299.05450.0539.4910.0150000.01000
    5,982 299.1450.0539.4950.0150000.01000
    5,983 299.15450.0539.4990.0150000.01000
    5,984 299.2450.0539.5030.0150000.01000
    5,985 299.25450.0539.5070.0150000.01000
    5,986 299.3450.0539.5110.0150000.01000
    5,987 299.35450.0539.5150.0150000.01000
    5,988 299.4450.0539.5190.0150000.01000
    5,989 299.45450.0539.5230.0150000.01000
    5,990 299.5450.0539.5270.0150000.01000
    5,991 299.55450.0539.5310.0150000.01000
    5,992 299.6450.0539.5350.0150000.01000
    5,993 299.65450.0539.540.0150000.01000
    5,994 299.7450.0539.5440.0150000.01000
    5,995 299.75450.0539.5480.0150000.01000
    5,996 299.8450.0539.5520.0150000.01000
    5,997 299.85450.0539.5560.0150000.01000
    5,998 299.9450.0539.560.0150000.01000
    5,999 299.95450.0539.5640.0150000.01000
    6,000 300.0450.0539.5680.0150000.01000

    Source and citation

    Data source: Own measurement series, recorded on the model function compute_step (step size Δt = 0.05 s) according to the test log of the bachelor thesis (2026); set-up and evaluation see Chapter 10 — Five test scenarios.

    How to cite

    Kotsch, A. H. (2026): Dataset „Scenario 2 — Heating with PT1 behaviour“ (6,000 rows, time 0.05–300.00 s). Supplement to the bachelor thesis „Digital twins for PLC-coupled laboratory systems“, Duale Hochschule Sachsen — Studienakademie Glauchau. https://thesis.kotsch.tech/daten/szenario-2-heizen (accessed 2026-09-30).

    Limits of this data
    • Classification (chapter 10): The deviations are compatible with the discretisation error of the Euler method.
    • Limit: The expectation uses the same parameters (τ = 12 s, 150 kW); what is tested is the implementation of the equations, not their agreement with a real heating element.
    • The expected values come from hand calculation and the analytical solution with the parameters of the model; agreement shows the correct implementation, not the accuracy compared with a real tank. Each scenario covers a single run with fixed boundary conditions. (Chapter 10)
    • Without measurement data from a real tank, validation is limited to internal consistency. (Chapter 11)

    More datasets