Data series · Chapter 10

Scenario 3 — Pressure build-up and venting

Continued heating up to boiling. B4 switches in the first step after 2.8 bar is exceeded (t = 1470 s); after 120 s of venting the pressure is back at 0.0 bar.

Scenario
3 Pressure build-up
Expectation (criterion)
B4 when 2.8 bar is exceeded
Measurement
B4 in the first step thereafter (t = 1470.45 s); 0.0 bar after 120 s of venting
Result
passed
Rows
25,809
Time range
300.05–1,590.45 s
Time step
Δt = 0.05 s
Columns
9

Time series

Each quantity has its own axis and unit in its own panel; all share the time axis. The sensor bits appear as step lines. Clicking the legend shows or hides a quantity.

Time series of the measurement

Building the chart …

Quantities (click to show or hide)

    Controls: ← → move cursor (with ⇧ ten times) · Pos1 Ende to the edge · + − zoom · Bild↑ Bild↓ pan · 0 full series · Esc remove cursor. Drag a region with the mouse to zoom in. Values at the cursor belong to the nearest plotted data point; when zoomed far out the chart shows the minimum and maximum per pixel bucket so that single peaks stay visible. Exact values: zoom in or use the tables.

    Column description

    Name and unit come from the header row of the CSV file; the meaning follows the heated-tank model (chapter 8) and the recording (chapter 10).

    Columns of the series — Scenario 3 — Pressure build-up and venting
    No.Column (CSV header) UnitTypeMeaning
    1 Zeit (s) s Time axis Time stamp of the row (model time); one row per calculation step of Δt = 0.05 s.
    2 Füllstand (l) l Process variable Water level in the tank (tank volume 0.5 m³ = 500 l).
    3 Temperatur (°C) °C Process variable Water temperature, calculated from energy and water mass.
    4 Druck (bar) bar Process variable Pressure in the head space (steam and air, partial pressures added).
    5 Heizleistung (W) W Process variable Currently effective heating power (PT1 lag, τ = 12 s, up to 150 kW).
    6 B1 Füllstand max — Sensor bit (0/1) Upper level sensor: 1 from 450 l, otherwise 0.
    7 B2 Füllstand min — Sensor bit (0/1) Lower level sensor: 1 at 50 l or less, otherwise 0.
    8 B3 Temperatur ≥95 °C — Sensor bit (0/1) Temperature sensor: 1 from 95 °C, otherwise 0.
    9 B4 Druck ≥2,8 bar — Sensor bit (0/1) Pressure sensor: 1 from 2.8 bar, otherwise 0.

    Statistics of the series

    All figures are computed from the rows of the CSV file (over the whole series, without smoothing) and describe this single run only. They make no statement about a real tank.

    25,809Rows (calculation steps)
    1,290.45stime covered
    0.05sTime step Δt
    8recorded quantities
    Statistics per process variable — Scenario 3 — Pressure build-up and venting
    QuantityUnit CountMinimum MaximumMean First valueLast value
    Füllstand l 25,809 404.91t = 1,590.45 s 450.05t = 300.05 s 444.898 450.05 404.91
    Temperatur °C 25,809 39.572t = 300.05 s 122.732t = 1,470.40 s 87.1250 39.572 100.511
    Druck bar 25,809 0.0000t = 300.05 s 2.8048t = 1,470.45 s 0.3462 0.0000 0.0000
    Heizleistung W 25,809 150,000.0constant 150,000.0 150,000.00 150,000.0 150,000.0

    Below each extreme value is the time of the first row with that value. The mean is the simple mean over all rows (equal time steps).

    Sensor bits: switching times — Scenario 3 — Pressure build-up and venting
    Sensor bit Rows with 1 Share first 1 at then 0 again at Changes
    B1 Füllstand max 15,020 58.197 % 300.05 sfirst row 1,051.05 s 1
    B2 Füllstand min 0 0.000 % — — 0
    B3 Temperatur ≥95 °C 12,184 47.208 % 981.30 s — 1
    B4 Druck ≥2,8 bar 1 0.004 % 1,470.45 s 1,470.50 s 2

    1 means the sensor is active (threshold reached), 0 not active (chapter 8). “Changes” counts the rows in which the value differs from the previous row.

    Values

    All rows of the CSV file, unchanged, 100 rows per page. Search and sorting run on the server; you can jump to a row or a time. “No.” is a running row number and not part of the CSV.

    1,001–1,100 of 25,809 rows Download CSV
    Values — Scenario 3 — Pressure build-up and venting
    No. Zeit (s) Füllstand (l) Temperatur (°C) Druck (bar) Heizleistung (W) B1 Füllstand max B2 Füllstand min B3 Temperatur ≥95 °C B4 Druck ≥2,8 bar
    1,001 350.05450.0543.640.0150000.01000
    1,002 350.1450.0543.6440.0150000.01000
    1,003 350.15450.0543.6480.0150000.01000
    1,004 350.2450.0543.6520.0150000.01000
    1,005 350.25450.0543.6570.0150000.01000
    1,006 350.3450.0543.6610.0150000.01000
    1,007 350.35450.0543.6650.0150000.01000
    1,008 350.4450.0543.6690.0150000.01000
    1,009 350.45450.0543.6730.0150000.01000
    1,010 350.5450.0543.6770.0150000.01000
    1,011 350.55450.0543.6810.0150000.01000
    1,012 350.6450.0543.6850.0150000.01000
    1,013 350.65450.0543.6890.0150000.01000
    1,014 350.7450.0543.6930.0150000.01000
    1,015 350.75450.0543.6970.0150000.01000
    1,016 350.8450.0543.7010.0150000.01000
    1,017 350.85450.0543.7050.0150000.01000
    1,018 350.9450.0543.7090.0150000.01000
    1,019 350.95450.0543.7130.0150000.01000
    1,020 351.0450.0543.7180.0150000.01000
    1,021 351.05450.0543.7220.0150000.01000
    1,022 351.1450.0543.7260.0150000.01000
    1,023 351.15450.0543.730.0150000.01000
    1,024 351.2450.0543.7340.0150000.01000
    1,025 351.25450.0543.7380.0150000.01000
    1,026 351.3450.0543.7420.0150000.01000
    1,027 351.35450.0543.7460.0150000.01000
    1,028 351.4450.0543.750.0150000.01000
    1,029 351.45450.0543.7540.0150000.01000
    1,030 351.5450.0543.7580.0150000.01000
    1,031 351.55450.0543.7620.0150000.01000
    1,032 351.6450.0543.7660.0150000.01000
    1,033 351.65450.0543.770.0150000.01000
    1,034 351.7450.0543.7740.0150000.01000
    1,035 351.75450.0543.7790.0150000.01000
    1,036 351.8450.0543.7830.0150000.01000
    1,037 351.85450.0543.7870.0150000.01000
    1,038 351.9450.0543.7910.0150000.01000
    1,039 351.95450.0543.7950.0150000.01000
    1,040 352.0450.0543.7990.0150000.01000
    1,041 352.05450.0543.8030.0150000.01000
    1,042 352.1450.0543.8070.0150000.01000
    1,043 352.15450.0543.8110.0150000.01000
    1,044 352.2450.0543.8150.0150000.01000
    1,045 352.25450.0543.8190.0150000.01000
    1,046 352.3450.0543.8230.0150000.01000
    1,047 352.35450.0543.8270.0150000.01000
    1,048 352.4450.0543.8310.0150000.01000
    1,049 352.45450.0543.8360.0150000.01000
    1,050 352.5450.0543.840.0150000.01000
    1,051 352.55450.0543.8440.0150000.01000
    1,052 352.6450.0543.8480.0150000.01000
    1,053 352.65450.0543.8520.0150000.01000
    1,054 352.7450.0543.8560.0150000.01000
    1,055 352.75450.0543.860.0150000.01000
    1,056 352.8450.0543.8640.0150000.01000
    1,057 352.85450.0543.8680.0150000.01000
    1,058 352.9450.0543.8720.0150000.01000
    1,059 352.95450.0543.8760.0150000.01000
    1,060 353.0450.0543.880.0150000.01000
    1,061 353.05450.0543.8840.0150000.01000
    1,062 353.1450.0543.8880.0150000.01000
    1,063 353.15450.0543.8920.0150000.01000
    1,064 353.2450.0543.8970.0150000.01000
    1,065 353.25450.0543.9010.0150000.01000
    1,066 353.3450.0543.9050.0150000.01000
    1,067 353.35450.0543.9090.0150000.01000
    1,068 353.4450.0543.9130.0150000.01000
    1,069 353.45450.0543.9170.0150000.01000
    1,070 353.5450.0543.9210.0150000.01000
    1,071 353.55450.0543.9250.0150000.01000
    1,072 353.6450.0543.9290.0150000.01000
    1,073 353.65450.0543.9330.0150000.01000
    1,074 353.7450.0543.9370.0150000.01000
    1,075 353.75450.0543.9410.0150000.01000
    1,076 353.8450.0543.9450.0150000.01000
    1,077 353.85450.0543.9490.0150000.01000
    1,078 353.9450.0543.9530.0150000.01000
    1,079 353.95450.0543.9580.0150000.01000
    1,080 354.0450.0543.9620.0150000.01000
    1,081 354.05450.0543.9660.0150000.01000
    1,082 354.1450.0543.970.0150000.01000
    1,083 354.15450.0543.9740.0150000.01000
    1,084 354.2450.0543.9780.0150000.01000
    1,085 354.25450.0543.9820.0150000.01000
    1,086 354.3450.0543.9860.0150000.01000
    1,087 354.35450.0543.990.0150000.01000
    1,088 354.4450.0543.9940.0150000.01000
    1,089 354.45450.0543.9980.0150000.01000
    1,090 354.5450.0544.0020.0150000.01000
    1,091 354.55450.0544.0060.0150000.01000
    1,092 354.6450.0544.010.0150000.01000
    1,093 354.65450.0544.0150.0150000.01000
    1,094 354.7450.0544.0190.0150000.01000
    1,095 354.75450.0544.0230.0150000.01000
    1,096 354.8450.0544.0270.0150000.01000
    1,097 354.85450.0544.0310.0150000.01000
    1,098 354.9450.0544.0350.0150000.01000
    1,099 354.95450.0544.0390.0150000.01000
    1,100 355.0450.0544.0430.0150000.01000

    Source and citation

    Data source: Own measurement series, recorded on the model function compute_step (step size Δt = 0.05 s) according to the test log of the bachelor thesis (2026); set-up and evaluation see Chapter 10 — Five test scenarios.

    How to cite

    Kotsch, A. H. (2026): Dataset „Scenario 3 — Pressure build-up and venting“ (25,809 rows, time 300.05–1,590.45 s). Supplement to the bachelor thesis „Digital twins for PLC-coupled laboratory systems“, Duale Hochschule Sachsen — Studienakademie Glauchau. https://thesis.kotsch.tech/daten/szenario-3-druckaufbau (accessed 2026-09-30).

    Limits of this data
    • Classification (chapter 10): B4 is set in exactly the step in which the threshold is exceeded.
    • Limit: The calculated pressure follows a sawtooth pattern; the threshold is exceeded by a single pressure peak, and the moment depends on the fluctuation band. In twelve rows (from t = 1051.05 s) the level, rounded to 0.01 l, is 450.0 l while B1 is already 0; this is compatible with the rounding of the recording.
    • The expected values come from hand calculation and the analytical solution with the parameters of the model; agreement shows the correct implementation, not the accuracy compared with a real tank. Each scenario covers a single run with fixed boundary conditions. (Chapter 10)
    • Without measurement data from a real tank, validation is limited to internal consistency. (Chapter 11)