Data series · Chapter 10

Scenario 3 — Pressure build-up and venting

Continued heating up to boiling. B4 switches in the first step after 2.8 bar is exceeded (t = 1470 s); after 120 s of venting the pressure is back at 0.0 bar.

Scenario
3 Pressure build-up
Expectation (criterion)
B4 when 2.8 bar is exceeded
Measurement
B4 in the first step thereafter (t = 1470.45 s); 0.0 bar after 120 s of venting
Result
passed
Rows
25,809
Time range
300.05–1,590.45 s
Time step
Δt = 0.05 s
Columns
9

Time series

Each quantity has its own axis and unit in its own panel; all share the time axis. The sensor bits appear as step lines. Clicking the legend shows or hides a quantity.

Time series of the measurement

Building the chart …

Quantities (click to show or hide)

    Controls: ← → move cursor (with ⇧ ten times) · Pos1 Ende to the edge · + − zoom · Bild↑ Bild↓ pan · 0 full series · Esc remove cursor. Drag a region with the mouse to zoom in. Values at the cursor belong to the nearest plotted data point; when zoomed far out the chart shows the minimum and maximum per pixel bucket so that single peaks stay visible. Exact values: zoom in or use the tables.

    Column description

    Name and unit come from the header row of the CSV file; the meaning follows the heated-tank model (chapter 8) and the recording (chapter 10).

    Columns of the series — Scenario 3 — Pressure build-up and venting
    No.Column (CSV header) UnitTypeMeaning
    1 Zeit (s) s Time axis Time stamp of the row (model time); one row per calculation step of Δt = 0.05 s.
    2 Füllstand (l) l Process variable Water level in the tank (tank volume 0.5 m³ = 500 l).
    3 Temperatur (°C) °C Process variable Water temperature, calculated from energy and water mass.
    4 Druck (bar) bar Process variable Pressure in the head space (steam and air, partial pressures added).
    5 Heizleistung (W) W Process variable Currently effective heating power (PT1 lag, τ = 12 s, up to 150 kW).
    6 B1 Füllstand max — Sensor bit (0/1) Upper level sensor: 1 from 450 l, otherwise 0.
    7 B2 Füllstand min — Sensor bit (0/1) Lower level sensor: 1 at 50 l or less, otherwise 0.
    8 B3 Temperatur ≥95 °C — Sensor bit (0/1) Temperature sensor: 1 from 95 °C, otherwise 0.
    9 B4 Druck ≥2,8 bar — Sensor bit (0/1) Pressure sensor: 1 from 2.8 bar, otherwise 0.

    Statistics of the series

    All figures are computed from the rows of the CSV file (over the whole series, without smoothing) and describe this single run only. They make no statement about a real tank.

    25,809Rows (calculation steps)
    1,290.45stime covered
    0.05sTime step Δt
    8recorded quantities
    Statistics per process variable — Scenario 3 — Pressure build-up and venting
    QuantityUnit CountMinimum MaximumMean First valueLast value
    Füllstand l 25,809 404.91t = 1,590.45 s 450.05t = 300.05 s 444.898 450.05 404.91
    Temperatur °C 25,809 39.572t = 300.05 s 122.732t = 1,470.40 s 87.1250 39.572 100.511
    Druck bar 25,809 0.0000t = 300.05 s 2.8048t = 1,470.45 s 0.3462 0.0000 0.0000
    Heizleistung W 25,809 150,000.0constant 150,000.0 150,000.00 150,000.0 150,000.0

    Below each extreme value is the time of the first row with that value. The mean is the simple mean over all rows (equal time steps).

    Sensor bits: switching times — Scenario 3 — Pressure build-up and venting
    Sensor bit Rows with 1 Share first 1 at then 0 again at Changes
    B1 Füllstand max 15,020 58.197 % 300.05 sfirst row 1,051.05 s 1
    B2 Füllstand min 0 0.000 % — — 0
    B3 Temperatur ≥95 °C 12,184 47.208 % 981.30 s — 1
    B4 Druck ≥2,8 bar 1 0.004 % 1,470.45 s 1,470.50 s 2

    1 means the sensor is active (threshold reached), 0 not active (chapter 8). “Changes” counts the rows in which the value differs from the previous row.

    Values

    All rows of the CSV file, unchanged, 100 rows per page. Search and sorting run on the server; you can jump to a row or a time. “No.” is a running row number and not part of the CSV.

    5,201–5,300 of 25,809 rows Download CSV
    Values — Scenario 3 — Pressure build-up and venting
    No. Zeit (s) Füllstand (l) Temperatur (°C) Druck (bar) Heizleistung (W) B1 Füllstand max B2 Füllstand min B3 Temperatur ≥95 °C B4 Druck ≥2,8 bar
    5,201 560.05450.0560.7260.0150000.01000
    5,202 560.1450.0560.7310.0150000.01000
    5,203 560.15450.0560.7350.0150000.01000
    5,204 560.2450.0560.7390.0150000.01000
    5,205 560.25450.0560.7430.0150000.01000
    5,206 560.3450.0560.7470.0150000.01000
    5,207 560.35450.0560.7510.0150000.01000
    5,208 560.4450.0560.7550.0150000.01000
    5,209 560.45450.0560.7590.0150000.01000
    5,210 560.5450.0560.7630.0150000.01000
    5,211 560.55450.0560.7670.0150000.01000
    5,212 560.6450.0560.7710.0150000.01000
    5,213 560.65450.0560.7750.0150000.01000
    5,214 560.7450.0560.7790.0150000.01000
    5,215 560.75450.0560.7830.0150000.01000
    5,216 560.8450.0560.7870.0150000.01000
    5,217 560.85450.0560.7920.0150000.01000
    5,218 560.9450.0560.7960.0150000.01000
    5,219 560.95450.0560.80.0150000.01000
    5,220 561.0450.0560.8040.0150000.01000
    5,221 561.05450.0560.8080.0150000.01000
    5,222 561.1450.0560.8120.0150000.01000
    5,223 561.15450.0560.8160.0150000.01000
    5,224 561.2450.0560.820.0150000.01000
    5,225 561.25450.0560.8240.0150000.01000
    5,226 561.3450.0560.8280.0150000.01000
    5,227 561.35450.0560.8320.0150000.01000
    5,228 561.4450.0560.8360.0150000.01000
    5,229 561.45450.0560.840.0150000.01000
    5,230 561.5450.0560.8440.0150000.01000
    5,231 561.55450.0560.8490.0150000.01000
    5,232 561.6450.0560.8530.0150000.01000
    5,233 561.65450.0560.8570.0150000.01000
    5,234 561.7450.0560.8610.0150000.01000
    5,235 561.75450.0560.8650.0150000.01000
    5,236 561.8450.0560.8690.0150000.01000
    5,237 561.85450.0560.8730.0150000.01000
    5,238 561.9450.0560.8770.0150000.01000
    5,239 561.95450.0560.8810.0150000.01000
    5,240 562.0450.0560.8850.0150000.01000
    5,241 562.05450.0560.8890.0150000.01000
    5,242 562.1450.0560.8930.0150000.01000
    5,243 562.15450.0560.8970.0150000.01000
    5,244 562.2450.0560.9010.0150000.01000
    5,245 562.25450.0560.9050.0150000.01000
    5,246 562.3450.0560.910.0150000.01000
    5,247 562.35450.0560.9140.0150000.01000
    5,248 562.4450.0560.9180.0150000.01000
    5,249 562.45450.0560.9220.0150000.01000
    5,250 562.5450.0560.9260.0150000.01000
    5,251 562.55450.0560.930.0150000.01000
    5,252 562.6450.0560.9340.0150000.01000
    5,253 562.65450.0560.9380.0150000.01000
    5,254 562.7450.0560.9420.0150000.01000
    5,255 562.75450.0560.9460.0150000.01000
    5,256 562.8450.0560.950.0150000.01000
    5,257 562.85450.0560.9540.0150000.01000
    5,258 562.9450.0560.9580.0150000.01000
    5,259 562.95450.0560.9620.0150000.01000
    5,260 563.0450.0560.9660.0150000.01000
    5,261 563.05450.0560.9710.0150000.01000
    5,262 563.1450.0560.9750.0150000.01000
    5,263 563.15450.0560.9790.0150000.01000
    5,264 563.2450.0560.9830.0150000.01000
    5,265 563.25450.0560.9870.0150000.01000
    5,266 563.3450.0560.9910.0150000.01000
    5,267 563.35450.0560.9950.0150000.01000
    5,268 563.4450.0560.9990.0150000.01000
    5,269 563.45450.0561.0030.0150000.01000
    5,270 563.5450.0561.0070.0150000.01000
    5,271 563.55450.0561.0110.0150000.01000
    5,272 563.6450.0561.0150.0150000.01000
    5,273 563.65450.0561.0190.0150000.01000
    5,274 563.7450.0561.0230.0150000.01000
    5,275 563.75450.0561.0280.0150000.01000
    5,276 563.8450.0561.0320.0150000.01000
    5,277 563.85450.0561.0360.0150000.01000
    5,278 563.9450.0561.040.0150000.01000
    5,279 563.95450.0561.0440.0150000.01000
    5,280 564.0450.0561.0480.0150000.01000
    5,281 564.05450.0561.0520.0150000.01000
    5,282 564.1450.0561.0560.0150000.01000
    5,283 564.15450.0561.060.0150000.01000
    5,284 564.2450.0561.0640.0150000.01000
    5,285 564.25450.0561.0680.0150000.01000
    5,286 564.3450.0561.0720.0150000.01000
    5,287 564.35450.0561.0760.0150000.01000
    5,288 564.4450.0561.080.0150000.01000
    5,289 564.45450.0561.0840.0150000.01000
    5,290 564.5450.0561.0890.0150000.01000
    5,291 564.55450.0561.0930.0150000.01000
    5,292 564.6450.0561.0970.0150000.01000
    5,293 564.65450.0561.1010.0150000.01000
    5,294 564.7450.0561.1050.0150000.01000
    5,295 564.75450.0561.1090.0150000.01000
    5,296 564.8450.0561.1130.0150000.01000
    5,297 564.85450.0561.1170.0150000.01000
    5,298 564.9450.0561.1210.0150000.01000
    5,299 564.95450.0561.1250.0150000.01000
    5,300 565.0450.0561.1290.0150000.01000

    Source and citation

    Data source: Own measurement series, recorded on the model function compute_step (step size Δt = 0.05 s) according to the test log of the bachelor thesis (2026); set-up and evaluation see Chapter 10 — Five test scenarios.

    How to cite

    Kotsch, A. H. (2026): Dataset „Scenario 3 — Pressure build-up and venting“ (25,809 rows, time 300.05–1,590.45 s). Supplement to the bachelor thesis „Digital twins for PLC-coupled laboratory systems“, Duale Hochschule Sachsen — Studienakademie Glauchau. https://thesis.kotsch.tech/daten/szenario-3-druckaufbau (accessed 2026-10-01).

    Limits of this data
    • Classification (chapter 10): B4 is set in exactly the step in which the threshold is exceeded.
    • Limit: The calculated pressure follows a sawtooth pattern; the threshold is exceeded by a single pressure peak, and the moment depends on the fluctuation band. In twelve rows (from t = 1051.05 s) the level, rounded to 0.01 l, is 450.0 l while B1 is already 0; this is compatible with the rounding of the recording.
    • The expected values come from hand calculation and the analytical solution with the parameters of the model; agreement shows the correct implementation, not the accuracy compared with a real tank. Each scenario covers a single run with fixed boundary conditions. (Chapter 10)
    • Without measurement data from a real tank, validation is limited to internal consistency. (Chapter 11)